In ความหมายของเครื่องวัดความดัน from chemistry laboratories to industrial services, in order to guarantee the safety of life and property against a potential hearth hazard, extinguishing techniques are used along with detection and alarm systems. It is also extraordinarily essential that the extinguishing techniques put in can be triggered by the hearth extinguishing control panel, in order to remove a attainable hearth with early intervention.
In order to satisfy these wants, and with 35 years of sectoral data and expertise, Mavili Elektronik presents:
Maxlogic Conventional Fire Extinguishing Control Panel working based on the cross-zone detection principle;
Maxlogic Extinguishing Status Indicator Unit, which permits the distant efficiency of the indications and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which allows the extinguishing course of to be started manually and remotely; and
to guarantee that the extinguishing process can be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
All these devices are produced using surface-mount expertise and are geared toward making the automation of the extinguishing system and fireplace and gasoline detection system perfect.
Image copyright: Mavili
Mavili Elektronik develops its merchandise by at all times contemplating the wants of the set up. In circumstances that require the combination of the extinguishing system with the clever addressable fireplace detection system, it offers options via the monitoring modules that also have a ‘supervised’ possibility.
Supervised monitoring modules play an important role in controlling the continuity of the cable connection between the loop and the extinguishing system. Failure to detect a possible open or short circuit in the wiring between the contact monitoring modules and the peripheral methods can cause disruption of the triggering, with potentially important consequences. For this cause, when selecting monitoring modules, it must be taken under consideration that they have supervised features.
Image copyright: Mavili
Since Maxlogic clever addressable fireplace detection and alarm management panels are constantly communicating with ‘supervise’ contact monitoring modules linked to cable loops and compliant with EN 54-17 and EN 54-18 requirements, it makes it easier to observe conditions corresponding to open circuits and brief circuits that may happen in the system. Many duties could be performed within the fire extinguishing set up, such because the control and monitoring of all valves that may interrupt the circulate of water, water circulate alarm switches, stress swap, and electrical or diesel fireplace pumps.
By including two contact monitoring modules to two separate relay outputs positioned above the Maxlogic Conventional Fire Extinguishing Control Panel, one of many modules can be utilized to manage errors and the opposite to regulate the fire state of affairs, monitoring and management of the extinguishing system through an intelligent addressable fire detection and alarm system may be carried out successfully.
For more data, go to www.mavili.com.tr/en