In many places from chemistry laboratories to industrial services, in order to ensure the safety of life and property in opposition to a possible fireplace hazard, extinguishing methods are used in addition to detection and alarm methods. It is also extremely important that the extinguishing techniques put in could be triggered by the fire extinguishing management panel, so as to eliminate a potential hearth with early intervention.
In order to satisfy these wants, and with 35 years of sectoral data and experience, Mavili Elektronik provides:
Maxlogic Conventional Fire Extinguishing Control Panel operating in accordance with the cross-zone detection principle;
Maxlogic Extinguishing Status Indicator Unit, which allows the distant performance of the indicators and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which allows the extinguishing process to be started manually and remotely; and
to make certain that the extinguishing course of can be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
All these gadgets are produced utilizing surface-mount technology and are aimed toward making the automation of the extinguishing system and fireplace and gasoline detection system excellent.
เกจวัดแรงดันแก๊สlpg : Mavili
Mavili Elektronik develops its merchandise by at all times considering the needs of the installation. In circumstances that require the combination of the extinguishing system with the intelligent addressable hearth detection system, it offers options via the monitoring modules that also have a ‘supervised’ choice.
Supervised monitoring modules play an necessary function in controlling the continuity of the cable connection between the loop and the extinguishing system. Failure to detect a potential open or quick circuit within the wiring between the contact monitoring modules and the peripheral methods can cause disruption of the triggering, with potentially important penalties. For this cause, when choosing monitoring modules, it must be taken into account that they’ve supervised options.
Image copyright: Mavili
Since Maxlogic clever addressable fireplace detection and alarm control panels are constantly speaking with ‘supervise’ contact monitoring modules related to cable loops and compliant with EN 54-17 and EN 54-18 requirements, it makes it easier to observe situations such as open circuits and brief circuits that may occur within the system. Many tasks can be carried out in the hearth extinguishing set up, such as the management and monitoring of all valves that can interrupt the flow of water, water flow alarm switches, stress swap, and electrical or diesel hearth pumps.
By including two contact monitoring modules to two separate relay outputs positioned above the Maxlogic Conventional Fire Extinguishing Control Panel, one of the modules can be used to regulate errors and the other to regulate the fireplace state of affairs, monitoring and management of the extinguishing system by way of an intelligent addressable hearth detection and alarm system may be performed successfully.
For more information, go to www.mavili.com.tr/en
Share

Leave a Reply